{"product_id":"brafgf120-eaton-circuit-breaker","title":"BRAFGF120 Eaton Circuit Breaker","description":"\u003ch2\u003eBRAFGF120\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEaton\u003c\/li\u003e\n\u003cli\u003eDual Function\u003c\/li\u003e\n\u003cli\u003eAF\/GF\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker\u003c\/li\u003e\n\u003cli\u003eWith Pigtail\u003c\/li\u003e\n\u003cli\u003e1 Pole\u003c\/li\u003e\n\u003cli\u003e20 Amp\u003c\/li\u003e\n\u003cli\u003e120V\u003c\/li\u003e\n\u003cli\u003eType BR\u003c\/li\u003e\n\u003cli\u003eWire Size: #14-8 AWG Cu\/Al\u003c\/li\u003e\n\u003cli\u003eNew\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSeries arc A low-current arc has been detected within one of the current pathways. Low-current arcs are typically series arcs, and are typically found in worn or degraded appliance and extension cords, poor connections in appliances or fixtures, or in contacts within equipment. 2 Parallel arc A high-current arc has been detected between two conductors. Look for damaged insulation usually found in installed wiring where the wire has been compromised by a nail or screw, tight staple, or damaged insulation. 3 Overload The circuit is drawing more current than the breaker is rated for. Remove some load from the circuit. 4 Overvoltage The breaker will trip if it experiences voltage of 160 V rms or greater. The breaker can be reset and the TEST button can be pushed to verify that the breaker is working properly. Most likely caused by a loose or floating neutral, either in the service entrance or at the transformer. 5 Ground fault \/ grounded neutral Current has found an alternate path to ground, or the neutral and ground are in contact downstream of the breaker; this could cause harm to people or property. 6 Self test failure The breaker continually tests the internal electronics and software to ensure that the arc fault and ground fault detection technology is working properly. If the self-diagnostics fail, the breaker will trip. The built-in self-test features will not allow the AF\/GF breaker to re-latch if it detects a malfunction in the AF\/GF detection circuit. Replace the breaker.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":52416773292312,"sku":"BRAFGF120","price":80.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0962\/6347\/1384\/files\/UE_SKUS_BRAFGF120_1_2104477b-5649-4319-952c-817ca9316413.jpg?v=1784467737","url":"https:\/\/breakeroutlet.com\/products\/brafgf120-eaton-circuit-breaker","provider":"Breaker Outlet","version":"1.0","type":"link"}